Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter

Product Details
Customization: Available
Material: Stainless Steel
Type: Medicine Cabinet
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
3D Software Design
The supplier provides 3D software design services
SDK Available
The supplier provides SDK
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
to see all verified strength labels (22)
  • Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter
  • Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter
  • Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter
  • Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter
  • Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter
  • Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter
Find Similar Products
  • Overview
  • Our Products
  • Our Advantages
  • Company Profile
  • Certifications
  • Equipment & Technique
  • Testing instrument
  • Packing & shipping & FAQ
Overview

Basic Info.

Usage
Hospital, School, Company, Research Institute
Color
White
Customized
Customized
Condition
New
Machinery Test Report
Provided
Warranty
1 Year
HEPA Filter
99.999% Efficiency
Function
Work Station
Noise
≤62dB
Transport Package
Export Wooden Case
Trademark
ACDT
Origin
Suzhou China
Production Capacity
50000PC/Year

Product Description

1:This is a completely closed cabinet, isolate operating personnel or objects to avoid damage by harmful substances, protective role.
2:It is often used in high-polluting, high toxicity, high hazard job.:
3:Exposure to toxic chemical biology, food testing, pharmaceutical and health 
hazardous industries ideal for devices.
4:Customized size and specification are available to meet customer's requirements.
Selection of Biological Safety Cabinet (BSC)
Catagory
Laboratory Type
Type of Protection
Class I
Group 1-3, microorganisms in Risk;
Slightly volatile, radionuclide/chemical protection
Operator, Environment
Class II A1
Group 1-3, microorganisms in Risk
Operator, Environment, Product
Class II A2
Group 1-3, microorganisms in Risk
Operator, Environment, Product
Class II B1
Group 1-3, microorganisms in Risk;
Slightly volatile, radionuclide/chemical protection
Operator, Environment, Product
Class II B2
Group 1-3, microorganisms in Risk;
Minute amounts volatile, radionuclide/chemical protection
Operator, Environment, Product
Class III
Group 1-3, microorganisms in Risk;
Volatile, radionuclide/chemical protection
Operator, Environment, Product
Class I BSC
Feature: Designed primarily for the protection of the operating personnel
Application: It is used for laboratories which are work with nonvolatile, radionuclide/checmial protection, microorganisms in risk. Exhaust System: External (hard duct)
BSC Grades
Inlet Air Velocity
% of Airflow
m/s
Internal Recirculation
Exhausted
Class I
0.38
0
100
Class II BSC
Feature: Designed not only to provide personnel protection but also to protect work surface materials from being contaminated by the room air which is drawn into the cabinet. And it is used for protecting the laboratory environment as well. It is acceptable for working with medium-level risk tests. And according to the National Sanitation Foundation Standard, NSF/ANSI 49(2002), it can be defined and classified as 4 types. Their features are compared as below.
Application: It is used for laboratories which are work with nonvolatile, radionuclide/checmial protection, microorganisms in risk. Exhaust System: Class II A1 & A2 - Internal or external (exhaust hood); Class II B1 & B2 - External (hard duct)
 
BSC Grades
Inlet Air Velocity
% of Airflow
m/s
Internal Recirculation
Exhausted
Class II A1
0.38
70
30
Class II A2
0.5
70
30
Class II B1
0.5
30
70
Class II B2
0.5
0
100
Class III BSC
Feature: Suitable for work in Bio-safety Level 3 and 4 laboratories and provide the protection for the highest hazardous level of the Risk Group 3, Risk Group 4, or above. It virtually is a sealed gas tight cabinet. Moreover, its supply air is HEPA- filtered and exhaust air passes through two HEPA filters which keep the cabinet interior under negative pressure consequently. The only way of accessing to the work surface for operation is by means of heavy duty rubber gloves, which are attached to ports in the cabinet virtually.
Application: It is used for laboratories which are work with lightly volatile, toxic, radionuclide protection, microorganisms in risk. Exhaust System: Exhaust air should pass through two filters.
 
BSC Grades
Inlet Air Velocity
% of Airflow
m/s
Internal Recirculation
Exhausted
Class III
N/A
0
100
Product Paramenters
Type: Class II A2
Model Number
BA2-4
BA2-5
BA2-6
External Dimension
W1450*D827*H2200 mm
W1750*D827*H2200 mm
W2050*D827*H2200 mm
Internal Dimension
W1250*D600*H650 mm
W1550*D600*H650 mm
W1850*D600*H650 mm
Body Construction
1.5t SUS 304
HEPA Filter (H14)
1170*450*70 mm
1470*450*70 mm
1770*450*70 mm
Exhaust Filter (H14)
520*460*100 mm
700*460*100 mm
1000*460*100 mm
Blower/Fan
EC brushless frequency converter motor
Air In Flow
100 FPM
Air Down Flow
60 FPM
Air Circulation
70%
Air Exhaust
30%
Lighting
> 600 lux (compliance to NSF 49)
UV Light
254 nm
Noise Level
< 65 dBA (compliance to EN 12469)
Compliance Standard
NSF 49, EN 12469, JIS K 3800
Cleanliness Standard
ISO 14644-1 (within working area)
Lab/Hospital Class II Biological Safety Cabinet with HEPA FilterLab/Hospital Class II Biological Safety Cabinet with HEPA Filter
Our Products

Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter
Lab/Hospital Class II Biological Safety Cabinet with HEPA FilterLab/Hospital Class II Biological Safety Cabinet with HEPA FilterLab/Hospital Class II Biological Safety Cabinet with HEPA Filter

Our Advantages

Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter

Company Profile

Lab/Hospital Class II Biological Safety Cabinet with HEPA FilterLab/Hospital Class II Biological Safety Cabinet with HEPA FilterLab/Hospital Class II Biological Safety Cabinet with HEPA FilterLab/Hospital Class II Biological Safety Cabinet with HEPA Filter

Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter

Certifications
Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter
Manufcturing license of the medical devices
License No. QMS2094
 
In order to get the manufacturing license, our company has passed the inspection against the Medical Device Quality Management System Regulations.
 
QMS, Quality Management System also known as GMP.
It is to ensure our device is able to be consistently produced and controlled by the proper quality standards.
 
We are the only one Taiwan company in our industry pass the QMS inspection.
Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter
ISO 13485: 2016
ISO 13485 is an international standard that specifies requirements for quality management systems for the medical device manufacturers.
 
The purpose is to ensure the we can provide high standards of quality assurance and product safety for our products and services, increase consumer trust and loyalty, and enhance corporate image and market competitiveness.
 
Less than 1% of Taiwan companies in our industry register.
Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter
ISO 9001: 2015
ISO 9001 is an international standard that specifies requirements for quality management system.
 
This standard helps us to provide products and services with consistent quality.
Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter

ISO 14001: 2015
ISO 14001 is an international standard that focuses on how businesses and organizations manage their environmental impacts.
 
The standard provides a framework for establishing an effective Environmental Management System (EMS) to help us achieving environmental objectives and reduce the impact on the environment.
Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter
Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter
UL 507
UL 507 is a standard issued by Underwriters Laboratories for electric fans and electric fan accessories.
 
Our FFU is a critical product widely used in cleanroom environments, such as medical, pharmaceutical, semiconductor, and other high-purity applications.
 
By achieving this certification, our FFU proves that it meets the strictest safety and performance requirements, providing customers with higher quality and more reliable products.
 
Our customers can confidently use our product, knowing that it meets the highest standards of safety and performance.
Equipment & Technique

Lab/Hospital Class II Biological Safety Cabinet with HEPA FilterLab/Hospital Class II Biological Safety Cabinet with HEPA Filter

Testing instrument

Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter

Packing & shipping & FAQ

Lab/Hospital Class II Biological Safety Cabinet with HEPA Filter

Q1 / Are you a manufacturer or trading company?
We are a cleanroom equipment manufacturer and have more than 30 years of experience in the industry.
 
We provide customized services for our products, our professional design and engineering team can help you find what you need. Welcome to send us your product drawing and specification and we can discuss the details.
 
We can also help you develop new products, contact us now!
 
Q2 / Can I have a sample before mass production?
For some of our products, we can provide a free sample, the sample can also be customized according to your requirements, contact us for more information.
 
Q3 / How long is the warranty period?
We offer one year warranty for our products, including a free replacement for the spare parts.
 
As for the electrical components, we offer free replacement or repair within 3 months.